The Latest & Fastest 4-Channel Vibration Analyzer

Explore the most powerful Vibration Analyzer on the market.
Use multitasking tool in order to analyse your machinery.
Balancer, Thermal imaging camera, Ultrasound, Bump test, ODS, MCSA – you name it…

Measure 4 vibration signals and 4 process values (temperature, pressure etc.) along with speed synchronously. Triaxial sensor friendly, proximity probes for displacement measurement, ultrasound microphone, acoustic microphone, thermal imaging camera, current clamp meter, stethoscope and more.

Analyse your data on site and enjoy the big screen size for playing with variable cursors, bearing fault frequencies indication and FFTs in cascade. Touchscreen and keyboard is at your service whenever you need it.

Built-in Modules

  1. Analyzer
  2. Route
  3. Run Up
  4. Recorder
  5. Balancer
  6. FASIT (Expert System)
  7. Stethoscope
  8. Lubri
  9. Octave Analysis
  10. Bump Test
  11. ADS (Operating Deflection Shapes)
  12. Ultrasound
  13. Camera
  14. Picture Gallery
  15. IR Camera
Picture1
Picture2
Picture3
Picture4
Picture5
Picture6
Picture7
Picture8
Picture9
Picture10
Picture11
Picture12
Picture13
Picture14
Picture15
Picture16
Picture17
Picture18
Picture19
Picture20
Picture21
Picture22
Picture23
Picture24
Picture25
Picture26
Picture27
previous arrow
next arrow

Comparison of Acquisition Time – Adash and Conventional Analyser

Technical Specifications

Input channels:
4 x AC, ICP® power supply on/off
4 x DC for process values
1 x TACHO for speed probe/external trigger
Input range:
AC +/- 12 V peak-peak
DC +/- 24V
AD conversion:
24 bit, 64 bit internal signal processing
No AutoGain function!
Dynamic range S/N:
120 dB
Frequency ranges:
Maximum range: 1 Hz – 90 kHz (1 Ch, 194 kHz sampling)
Maximum range: 1 Hz – 25 kHz (4 Ch, 64 kHz sampling)
Minimum range: 1 Hz – 25 Hz (4 Ch, 64 Hz sampling)
Sampling mode:
Fully simultaneous for 4 channels
FFT resolution:
Min. 100 lines
Max. 3 276 800 lines
Unit modes:
Data collector – route measurements
Balancer – 1 and 2 plane on site balancing
Run up – run up and coast down measurements
Recorder – raw signal recording for later post analysis
Stethoscope – listening of the bearing/machine noise
FASIT – expert system for automatic fault detection
Octave analyzer – audible sound measurements
Bump test – measurement of natural frequencies
ADS – Animated Deflection Shapes (Operating deflection shapes)
Ultrasound – measurement of ultrasound in 30 – 50 kHz range
Camera – 5MP, 2592×1944 px resolution
IR Camera – 384×288 px resolution; NETD sensitivity 50mK
Gallery – Storage for picture, IR image, screenshots
 
Display:
Colour 1125 x 800 pixels, LCD
Processor:
Intel Atom 1.9 GHz
Memory, Route:
64 GB, max. 16 GB for one route, number of routes is limited by free
memory only
Data processing:
Real time FFT
DEMOD – ENVELOPE analysis
ACMT – low speed bearing analysis
Order analysis
User band pass analysis
RPM measurement
DC measurement
Orbit measurement
Raw signal recorder:
64 kHz sampling frequency
4 Ch memory consumption 3 GB/hour
4 Ch total recording – 20 hours
Trigger:
Manual, External, Signal level, Time
Use for signal recording trigger
Speed change, Time interval
Interface:
USB 3.0, 2.0 compatible
Operating temperature range:
-10˚C to +50˚C
Power:
Battery 8 hours of operation, AC 100-230 V
Case:
Aluminium heavy duty
Size & Weight:
295 x 230 x 49 mm, 2000 g

Data Sheet & Manual