4 to 16 channelsCompact size on-line monitoring system

The A3800 is a compact size on-line monitoring and diagnostic system designed to increase machine reliability. The compact size of the A3800 enables it to be placed directly on the DIN rail in the switchboard. The A3800 unit has an optional number of AC and DC input channels – 4, 8, 12 or 16. AC and DC channels are separate. This means that the 4-channel configuration allows you to connect 4 AC and 4 DC channels. Depending on the number of active input channels, we can use 1 – 4 independent TACHO inputs.

The number of active channels can be extended additionally by purchasing additional licenses. Each group of 4 channels allows fully simultaneous measurements. Groups of 4 input channels are switched to each other via a multiplex. The A3800 unit can be used also as a powerful multichannel analyzer. The setting and control of A3800 unit is done in DDS software.

Key Features

  • Optional number of input channels
  • 4 – 16 channels AC
  • 4 – 16 channels DC
  • 1 – 4 TACHO inputs
  • Adaptive algorithm of data acquisition
  • Compact size, DIN rail mounting
A3800_CM2
A3800_CM1
previous arrow
next arrow

Technical Specifications

Input channels AC:
4 – 16 AC, ICP® power supply on/off
input impedance 100kΩ
integration single, double
high pass filter 1 Hz – 12800 Hz
low pass filter 25 Hz – 25600 Hz
Input channels DC:
4 – 16 DC for process values
input impedance 100 kΩ (VDC), 250 Ω (mADC)
TACHO inputs:
1 – 4 independent TACHO for external trigger
speed range 0,8 Hz – 1000 Hz
Input range:
AC +/- 12 V peak-peak
DC +/- 24 V or 4 – 20 mA
TACHO +10V
AD conversion:
24 bit, 64 bit double floating point internal signal processing
No AutoGain function!
Dynamic range S/N:
120 dB
Frequency ranges:
max. 25,6 kHz (16 Ch, 65,5 kHz sampling)
Sampling mode:
Fully simultaneous for group of 4 channels
FFT resolution:
Min. 100 lines
Max. 25 600 lines
Processor:
Intel Atom E3815 – 1.46 GHz
Memory RAM:
2 GB
 
Internal hard drive:
SSD 32 GB
Data acquisition:
Overall values
Time signals
FFT real time analysis
DEMOD – ENVELOPE analysis
ACMT – low speed bearing analysis
order analysis
user band pass analysis
RPM measurement
DC measurement
Orbit measurement
Speed measurement
Signal Recorder:
64 kHz sampling frequency
4 Ch memory consumption 3 GB/hour
4 Ch total recording – 10 hours
Trigger:
free run, TACHO, external (voltage)
Communication:
Ethernet 1GB RJ45
Temperature range:
-10˚C to +50˚C
Power:
DC 12 V
Case:
aluminium box
Size & Weight:
117 x 117 x 58 mm (without connectors)
800 g